Check before you buy. Pump, noise, and warranty aren’t in our sources, so ask the seller.
Our read
Who it suits
At 9 pints a day, the CTH30E sits below the smallest size in the ENERGY STAR table. That size is 20 pints, for a damp room under 2,000 sq ft. Waykar lists two models with the same EPA figures, so compare prices.
Capacity suggested for each case, read Oct 5, 2026. ENERGY STAR adds that it’s better to oversize than undersize.
Running cost
A middle-of-the-pack power bill
It uses 117 kWh a year, the median for 13-pint and smaller models. The nine thriftiest of its size would each save $24 in the United States over 11 years, the DOE’s average life for a portable. One is the Concetta AS-CSJ72XK-2WT-OL.
The company that files it with the EPA lists the Waykar CTH30A and CTH30D with the same capacity, energy use, and efficiency. Compare their prices and warranties before you choose.
Ask before you buy
Ask how loud it is
No source we use gives a dB(A) figure for the CTH30E. For a bedroom or an office, ask the seller for one, and for the distance it was measured from.
Tied for 11th of 28 certified 13-pint and smaller portables for low energy use.
Its efficiency, 1.70 liters per kWh, is 31% above the federal minimum for its capacity class.The DOE sets 1.30 L/kWh for portables rated 25 pints a day or less. Every unit made since June 13, 2019, must meet it.
The smallest portable certified under the Kesnos name. Next up is the AKE1.5D, at 24 pints.That one uses 173 kWh a year more.
On the market since May 2025, newer than 4% of the 13-pint and smaller models on the list.
Not on the EPA’s Most Efficient list, which names 18 of the 13-pint and smaller models.
The company that files it also files the Fehom, Waykar, and Yaufey models with the EPA.
The nearest size from another brand is the Waykar CTH30A, rated 9 pints and 117 kWh a year.Both cost the same to run in the United States.
Our arithmetic
One full day of drying
Water
1.2gal
9.2 pints
Electricity
2.6kWh
liters ÷ IEF
Cost
$0.47
in the United States
A day of nonstop drying means 9.2 pints of water, about 1.1 gallons, for some 2.6 kWh. At the average home electricity price in the United States, the CTH30E costs $0.47 to run that day.
The EPA’s yearly estimate, 117 kWh, adds up to about 46 days like that. Each extra day at full output costs another $0.47.
Those 9.2 pints come from a DOE test at 65°F and 60% humidity. Cooler air at that humidity gives up less water, so expect fewer pints in a cold basement.
Every day at full output leaves 1.1 gallons to get rid of. Check how the CTH30E drains, since our sources don’t say.