Check before you buy. Pump, noise, and warranty aren’t in our sources, so ask the seller.
Our read
Who it suits
On the ENERGY STAR table, the TAURUS-RCS25(Y)-N4-3 suits a damp space under 2,000 sq ft. It’s too small for a very damp or wet one. Aeocky lists a model with the same EPA figures, so compare prices.
Capacity suggested for each case, read Oct 5, 2026. ENERGY STAR adds that it’s better to oversize than undersize.
Running cost
Its power bill is close to the norm
A portable lasts 11 years on average, by the DOE’s count. In that time, this model costs $6 more to run in the United States than the median 19–28 pint model. The thriftiest 19–28 pint model, the Knka PD30MA-20, would save $115 over those years.
The company that files it with the EPA lists the Aeocky LEO-RCS25(Y)-N4-3 with the same capacity, energy use, and efficiency. Compare their prices and warranties before you choose.
Ask before you buy
Ask for a noise figure
Our sources publish no noise level for the TAURUS-RCS25(Y)-N4-3. If it runs where you sleep or work, ask for a figure in dB(A), with the distance it was measured from.
Uses 287 kWh a year, 3 kWh over the median of its class.
Its refrigerant is R-32, flagged as lower GWP.Global warming potential 675.
No Wi-Fi app.Not listed as connected.
Of the 155 certified 19–28 pint portables, 110 use less energy, and 4 use exactly as much.
At 1.75 liters per kWh, it clears the federal minimum for its class by 35%.The DOE sets 1.30 L/kWh for portables rated 25 pints a day or less. Every unit made since June 13, 2019, must meet it.
Vellgoo’s next size up is the TAURUS-RCS25(Y)-N4-3-25, rated 25 pints.That one uses 1 kWh a year less.
Sold since February 2025. Among 19–28 pint models, 14 of 155 came out earlier.
Not on the EPA’s Most Efficient list, which names 31 of the 19–28 pint models.
The company that files it also files the Aeocky models with the EPA.
Another brand near this size: the Aeocky LEO-RCS25(Y)-N4-3, at 23 pints and 287 kWh a year.Both cost the same to run in the United States.
Our arithmetic
One full day of drying
Water
2.8gal
22.5 pints
Electricity
6.1kWh
liters ÷ IEF
Cost
$1.11
in the United States
In 24 hours at full output, the TAURUS-RCS25(Y)-N4-3 pulls about 2.8 gallons of water from the air and uses about 6.1 kWh. That day costs $1.11 in the United States.
About 47 such days make up the EPA’s yearly estimate of 287 kWh. If yours runs at full output more often, every extra day adds $1.11.
Its rating comes from a DOE test at 65°F and 60% humidity. In cooler air at that humidity, the TAURUS-RCS25(Y)-N4-3 pulls out less than 22.5 pints a day.
Those 2.8 gallons need a way out: a hose to a drain, a pump, or a bucket you empty. Our sources don’t say which ones the TAURUS-RCS25(Y)-N4-3 has.