Check before you buy. Pump, noise, and warranty aren’t in our sources, so ask the seller.
Our read
Who it suits
At 24 pints a day, the CTH80A fits a damp space under 2,000 sq ft. It’s too small for a very damp or wet one. Its running cost is close to the median, so drainage, noise, and price matter more.
Capacity suggested for each case, read Oct 5, 2026. ENERGY STAR adds that it’s better to oversize than undersize.
Running cost
A middle-of-the-pack power bill
Next to the median 19–28 pint model, this one costs $14 more to run in the United States over 11 years. That’s how long the DOE expects a portable to last. The thriftiest 19–28 pint model, the Knka PD30MA-20, would save $123 over those years.
Our sources publish no noise level for the CTH80A. If it runs where you sleep or work, ask for a figure in dB(A), with the distance it was measured from.
Uses 291 kWh a year, 7 kWh over the median of its class.
Its refrigerant is R-32, flagged as lower GWP.Global warming potential 675.
No Wi-Fi app.Not listed as connected.
Of the 155 certified 19–28 pint portables, 130 use less energy, and 8 use exactly as much.
At 1.75 liters per kWh, it clears the federal minimum for its class by 35%.The DOE sets 1.30 L/kWh for portables rated 25 pints a day or less. Every unit made since June 13, 2019, must meet it.
Waykar also makes it smaller, the YDA-32A at 12 pints, and bigger, the TDW80B at 25 pints.The bigger one uses 4 kWh a year less.
Sold since April 2026. Among 19–28 pint models, 106 of 155 came out earlier.
Not on the EPA’s Most Efficient list, which names 31 of the 19–28 pint models.
The company that files it also files the Fehom, Kesnos, and Yaufey models with the EPA.
Another brand near this size: the hOmeLabs HME0088, at 24 pints and 291 kWh a year.Both cost the same to run in the United States.
Our arithmetic
One full day of drying
Water
3.1gal
24.48 pints
Electricity
6.6kWh
liters ÷ IEF
Cost
$1.21
in the United States
In 24 hours at full output, the CTH80A pulls about 3.1 gallons of water from the air and uses about 6.6 kWh. That day costs $1.21 in the United States.
About 44 such days make up the EPA’s yearly estimate of 291 kWh. If yours runs at full output more often, every extra day adds $1.21.
Its rating comes from a DOE test at 65°F and 60% humidity. In cooler air at that humidity, the CTH80A pulls out less than 24.48 pints a day.
Those 3.1 gallons need a way out: a hose to a drain, a pump, or a bucket you empty. Our sources don’t say which ones the CTH80A has.