Check before you buy. Pump, noise, and warranty aren’t in our sources, so ask the seller.
Our read
Who it suits
At 38 pints a day, the Aegis H110 fits a wet space under 2,000 sq ft, or a damp one over. Its running cost is close to the median, so drainage, noise, and price matter more.
Capacity suggested for each case, read Oct 5, 2026. ENERGY STAR adds that it’s better to oversize than undersize.
Running cost
A middle-of-the-pack power bill
It uses 374 kWh a year, the median for 29–44 pint models. The thriftiest of its size, the Deciuu LIBRA-RCS32(Y)-N4-3(B), would save $83 in the United States over 11 years. That’s the DOE’s average life for a portable.
The EPA doesn’t list the Aegis H110 as connected. Of the 87 certified 29–44 pint models, 8 are. In a crawl space you rarely open, a connected one saves the trip.
Ask for the pump lift and the lowest working temperature
Pump and cold are the two blanks for the Aegis H110 in our sources. A pump matters when water can’t run down to a floor drain. Cold matters because below 65°F, ENERGY STAR says frost can form on the coils.
Its refrigerant is R-32, flagged as lower GWP.Global warming potential 675.
Tied for 40th of 87 certified 29–44 pint portables for low energy use.
Its efficiency, 2.01 liters per kWh, is 26% above the federal minimum for its capacity class.The DOE sets 1.60 L/kWh for portables rated over 25 and up to 50 pints a day. Every unit made since June 13, 2019, must meet it.
In the Moiswell lineup, the next size down is the Defender SP60R, at 24 pints. The next size up is the Defender HP150, at 50 pints.The bigger one uses 156 kWh a year more.
On the market since July 2026, newer than 93% of the 29–44 pint models on the list.Certified in July 2026, one of the 97 models certified in the last six months.
Not on the EPA’s Most Efficient list, which names 1 of the 29–44 pint models.
The nearest size from another brand is the Airecoler Sailing P120A, rated 38 pints and 374 kWh a year.Both cost the same to run in the United States.
Our arithmetic
One full day of drying
Water
4.8gal
38 pints
Electricity
8.9kWh
liters ÷ IEF
Cost
$1.64
in the United States
In 24 hours at full output, the Aegis H110 pulls about 4.8 gallons of water from the air and uses about 8.9 kWh. That day costs $1.64 in the United States.
About 42 such days make up the EPA’s yearly estimate of 374 kWh. If yours runs at full output more often, every extra day adds $1.64.
Its rating comes from a DOE test at 65°F and 60% humidity. In cooler air at that humidity, the Aegis H110 pulls out less than 38 pints a day.
Those 4.8 gallons need a way out: a hose to a drain, a pump, or a bucket you empty. Our sources don’t say which ones the Aegis H110 has.